One slice, standardised by vertebral level so that the same anatomy is measured at each visit. Software thresholds the image to fat density, and the visceral compartment is the fat inside the muscular abdominal wall, separated from the subcutaneous fat outside it. Reading is done centrally and blinded in a trial. Radiation exposure is small for one slice, which is a reason it was preferred to full volumetric scans.
Magnetic resonance methods now measure the whole volume without radiation and are replacing single-slice CT in newer trials.
A 15 per cent fall in cross-sectional area at one level is a modest change in a large depot — visibly less abdominal girth in some participants, not in others. Waist circumference fell by a few centimetres in parallel. The clinical meaning of the area change, as the European assessors noted, has not been tied to outcomes. Subcutaneous fat and limb fat did not change, which distinguishes the effect from weight loss.
The page on visceral and subcutaneous fat sets out the biology of the two compartments.
Because the headline number from the trials is a measurement with a method, and a reader should know what was measured before weighing the number. It describes a method and no use of the pack.
Tesamorelin is supplied by REVIVE LAB UAE for laboratory research use only, with identity by mass spectrometry and purity by HPLC for the batch. It is not for human or veterinary use, and no dosing, administration or protocol guidance is provided.
| Format | Strength | Price | Availability |
|---|---|---|---|
| Tesamorelin Pack | 20 mg | AED 1010 | In stock |
Delivery is AED 40 flat and free on orders over AED 700. Payment is cash on delivery anywhere in the UAE, or USDT (TRC20) in advance, which takes 5% off the order total.
One slice, standardised by vertebral level so that the same anatomy is measured at each visit. Software thresholds the image to fat density, and the visceral compartment is the fat inside the muscular abdominal wall, separated from the subcutaneous fat outside it. Reading is done centrally and blinded in a trial. Radiation exposure is small for one slice, which is a reason it was preferred to full volumetric scans.
No. REVIVE LAB UAE supplies research materials and provides no dosing, administration or protocol guidance of any kind. Every product is sold for laboratory research use only and is not for human or veterinary consumption.
Stock is held in Dubai. An order confirmed before 4 PM Dubai time is dispatched the same working day, reaching Dubai and Abu Dhabi the same day and the remaining emirates within 24 hours. Delivery is AED 40 flat and free over AED 700.
Supplied for laboratory research use only. Not for human or veterinary consumption. REVIVE LAB UAE provides no dosing, administration or protocol guidance.